Deciphering error codes and malfunctions of Ballu air conditioners. Common error codes for air conditioners Error e9 split system


Both domestic and industrial air conditioning systems, for the most part, have self-diagnosis function. This function can work in automatic mode or in a special mode if there is a problem with the equipment. As a rule, information with error codes can be observed on the displays located on the indoor units of the split systems. Thanks to this data, malfunctions due to which malfunctions in the air conditioning system have occurred are precisely determined. To independently determine the causes of problems in devices different manufacturers you can use the lists of error codes for various air conditioners, provided below by brand name.

In LG air conditioning systems, the microprocessor, when a malfunction is detected, blocking the start of the unit, after which it gives signals by flashing the LED, which report the error code.

If the system has detected several problems, then the breakdown that has the smallest sequence number is induced first. After that, there is an indication of faults in ascending order. The table below shows the error codes for LG air conditioners and explains what each of them means.

You should know: the occurrence of similar errors can be triggered by unsatisfactory parameters electrical network, or an accidental failure that occurred in the electronics of the unit. Therefore, do not rush to immediately contact the service, but simply turn off the device and check electrical voltage. It is also necessary to make sure that the correct device operating mode. After these checks, you can turn on the machine. Most often, this method helps in solving this problem, and it no longer appears.

The set of symbols for faults detected by the microprocessor depends on the model of the unit. For LG air conditioners, there may be another indication - in the form of numbers and letters.

Evaporator unit faults:

Capacitor block defect designations:

Designations in LG Art Cool units:

Daikin

Daikins are pretty sophisticated equipment(from a technical point of view) and, in addition to the refrigeration unit, have electronic control boards, many various sensors and valves, power inverter and other components. If any component of the device fails, it is difficult to find the cause of the breakdown without a special function that allows you to diagnose the equipment. This procedure is carried out using the remote control, and error codes Daikin air conditioners in case of malfunction of the device can be seen on its display.

Daikin evaporator unit problems:





Faults in the system:

Other problems:


Panasonic

Panasonic air conditioner error codes are usually displayed on display located on the wall-mounted (room) unit of the unit. They can be recognized by pressing the “CHECK” button on the remote control and holding it for at least 5 seconds.

Since only a hole is visible instead of a button on the remote control, you can use a paper clip to press the recessed button, if it is straightened, or a small carnation.

After the remote control enters the error checking mode of Panasonic air conditioners, point it towards the indoor unit of the device and by pressing the buttons designed to control the timer (“up” and “down” arrows), start to cycle through the codes, starting from “H00” and further, by order. If the fault code matches in the memory of the wall unit and on the remote control, you will hear sound signal. To exit the check mode, press the “CHECK” button again.

Explanation of values ​​for Panasonic units:



Toshiba

The remote control of Toshiba Ras cooling systems also has a “CHECK” button that activates the self-diagnosis of the unit.

Fault codes in household systems Toshiba air conditioners (Toshiba RAS-07S3KHS-EE / RAS-07S3AHS-EE, Toshiba RAS-10EKV-EE / RAS-10EAV-EE):

Also, these values ​​are applicable for RAS-10SKHP-ES, RAS-13SKHP-ES, RAS-13S2AH-ES, RAS-07S2AH-ES, RAS-10S2AH-ES, RAS-07SKHP-ES and others.

Toshiba Industrial Conder Trouble Codes:




ballu

Ballu air conditioner error codes, as usual, are displayed on display evaporator indoor unit. Each time Balu's climate control equipment is turned on, the microprocessor performs a self-diagnosis of the equipment and, in case of problems, displays special symbols on a miniature screen.

Decryption for devices brand Ballu:

Gree

If, when the air conditioner is turned on, the self-diagnosis system detects a malfunction in any module of the device, then its start is instantly blocked. At the same time, all error codes of Gree air conditioners can be observed either on the screen of the remote control or on the display of the indoor unit of the unit.

List of malfunctions of Gree air conditioning units:


General Climate

Alphanumeric designations of problems that are highlighted on the remote control:

Errors that are displayed on the wall unit display(domestic) General Climate:

Some of the General Climate air conditioner error codes above allow the user to independently find the problem and fix it. In other cases, for example, if the def / fan (pre / def) indicator flashes, specialist assistance is required.

Samsung

To start self-diagnostics of Samsung equipment, you need to start the operation of the conder in test mode. To do this, hold the split system start button for 5 seconds. Error codes for Samsung air conditioners, when detected, are displayed on the display of the unit located indoors.

Malfunctions in the operation of Samsung split systems:


Mitsubishi

For troubleshooting in technology from Mitsubishi, it is necessary within 4 seconds. hold on the remote control (simultaneously) 2 buttons: “CHECK” and “SET”. If problems are found, air conditioner error codes Mitsubishi Electric displayed on the display of the indoor unit or remote controller.


In addition to the above errors of the Mitsubishi Electric air conditioner, there are generic error codes related to different models Mitsubishi Electric units:

  • error E6 or EE - problems were detected in the connection between the unit located outside and the indoor unit. There is no signal from the sensor, or a short circuit is detected;
  • code E5 - malfunctions were detected during the operation of the equipment, it is also necessary to check the electrical voltage in the network.

Hitachi

The tables below show the error codes for Hitachi air conditioners. In Hitachi units, malfunctions are determined by blinking indicators.

TCL

Error codes in TCL climate systems (air conditioners) can be deciphered using the table below (the number of LED flashes in 8 seconds means an error code).


ideas

In Idea units, all problems detected by the processor at startup are highlighted on the air conditioner display.

AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Vitek, digital display for air conditioner series fault:

  • Display mode = E4
  • Priority level display = 1 Non-mitsubishi52_63_71he-s power supply failure = Plastic temp sensor is abnormal.
  • Display mode = E1 Priority level display = 2
  • Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3
  • Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = E2 Priority level display =
    4

2. H series, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Renova (except KFR-25G/H) h3 HA HB series fault display:

  1. Power supply failure = PG feedback engine abnormal
  2. Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = Timer LED blinks 1 time every 8 seconds
  3. Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds
  4. Priority level display = 3 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 1 time every 1 second
  5. Priority level display = 4

3. Series H (Y) air conditioner model remote display, removable panel AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu:

  1. Power supply failure = Motor feedback PG abnormal Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1
  2. Power supply failure = Plastic temp sensor. abnormal Display mode = Timer LED flashes 1 time every 8 seconds Priority level display = 2
  3. Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3
  4. Power supply failure = Copper temperature sensor abnormal (open, no signal) Display mode = Timer LED flashes 1 time every 1 second Priority level display = 4

4. E. E. E. EU EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display air conditioner series AUX, DAX, Renova, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu(Daihatsu), Troubleshooting:

AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu power supply failure = Motor feedback PG abnormal Display mode = E4 Priority level display = 1

E1 or EL - as a common nutrition mistake.

Power supply failure or, in Russian, mains voltage< 210 В (сработала защита – токовая нагрузка) = Датчик темп ненормально Режим отображения = E1 Отображение уровня приоритета = 2

E1 - pretty common mistake, just yesterday I encountered.

    The reasons for E1 are obvious - insufficient voltage in the network< 210 В. При пуске компрессора происходит дополнительная просадка напряжения, токовая нагрузка max.
    Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = E3 Priority level display = 3

1

1

5. All other E series except EA EU E.M.E.U.Z. EAA EAD:

Power supply failure = PG motor feedback abnormal

Display mode = Timer LED blinks 4 times every 8 seconds

Priority level display = 1 Power supply failure = Plastic temp. abnormal Display mode = Timer LED blinks 1 time every 8 seconds

Priority level display = 2 Power supply failure = Copper temperature sensor abnormal (indoor) Display mode = Timer LED blinks 2 times every 8 seconds Priority level display = 3

6. QA QB QD digital display of AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Vitek, Renova air conditioners - malfunctions, error codes:

  • Power supply failure = PG motor feedback abnormal Display mode = E4
  • Priority level display = 1 Power supply failure = Plastic temp sensor abnormal Display mode = E1
  • Priority level display = 2 Power supply failure = Copper temperature sensor abnormal
  • Display mode = E3 Priority level display = 3 Power supply failure = overcurrent oprotection
  • Display mode = E6 Priority level display = 4

1

1

7. QC QQ light display air conditioner series fault:

  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 4 times every 8 seconds Priority level display = 1 Power supply failure = Plastic temp sensor abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2 Power supply failure AUX, DAX, JAX, Pioneer, Vitek, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu = Copper temperature sensor abnormal
  • Display mode = Timer LED blinks 3 times every 8 seconds Priority level display = 3 Power supply failure = over current oprotection
  • Display mode = Timer LED blinks 6 times every 8 seconds Priority level display = 4

1

1

8. Display faults of 18000BTU ~ 24000BTU, AUX, DAX, JAX, Pioneer, Hansa, Saturn, Rolsen, Yamatsu, Daihatsu, Renova series - wall mounted air conditioner series:

  • Numbers for digital tube displays:
  • Power supply failure = PG motor feedback abnormal
  • Display mode = Timer LED blinks 1 time every 8 seconds Priority level display = 2
  • System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode =
  • Timer LED blinks 2 times every 8 seconds Priority level display = 3 System errors = turns off
  • Power supply failure = Copper temperature sensor abnormal Display mode = Timer LED blinks 8 times every 8 seconds Priority level display = 4
  • System errors = not turning off Digital tube displays: Power supply failure = PG motor feedback abnormal Display mode = E1
  • Priority level display = 2 System errors = turns off Power supply failure = Plastic temp sensor abnormal Display mode = E3
  • Priority level display = 3 System errors = turn off Power supply failure = Copper temperature sensor abnormal Display mode = E2 Priority level display = 4
  • System errors = does not turn off

Air conditioner error codes allow service engineer quickly find and efficiently fix faults.

Air conditioner diagnostics

This is the first thing to do before servicing or repairing it. Diagnostics of the air conditioner allows you to identify breakdowns and malfunctions in the system. Whether it is a lack of refrigerant that needs to be replenished, errors in the operation of the air conditioner, or malfunctions of the main components.

Timely and competent diagnostics of malfunctions will allow the service engineer to quickly and efficiently eliminate malfunctions. So, to return a healthy microclimate to the client's home or office.

All modern air conditioners have a developed self-diagnosis system. As a result of analyzing the state of the equipment, the system identifies the cause of the malfunction and displays the error code on the display (of the remote control, board or mode indicator). Below are the error codes of air conditioners (alarm code) of various brands. Using this information, you can independently read the error code and repair the air conditioner. This will significantly save the time of equipment diagnostics and avoid inaccuracies in determining the nature and location of the breakdown.

Air conditioner error codes

We have selected for you information about error codes for air conditioners and split systems of different brands.

If you need an authorized service center for air conditioner repair - it's for us! EUROBUSINESS is your reliable partner!

Error codes for Beko BKN, AKN air conditioners

⊕ - blinking, 2 - on, 3 - off. If there are these errors, the operation of the air conditioner will be automatically terminated.

Error codes for Beko AKH, AKP, AS, BKH, BKP, BS air conditioners

Error codes for Beko inverter air conditioners BKC 090 INV, BKC 120 INV, BKL090 INV, BKL120 INV

If the BEKO air conditioner does not work, this is for us!

Error codes for Carrier air conditioners

If a malfunction is detected, the green indicator (P) and the orange indicator (R) flash at a frequency of 0.1 seconds, indicating a fault code. It should be noted that the orange indicator (R) corresponds to the tens in the number - the fault code. The green indicator (P) corresponds to the units in the number - the fault code.
There are 2 seconds between blinking orange and green indicators. The sequence is repeated at intervals of 4 seconds.

For example, fault code 13. Orange LED flashes once, both LEDs are off for 2 seconds, green LED flashes three times at 0.5 second intervals, both LEDs are off for 4 seconds.
The sequence is repeated until the fault is corrected. If the fault code is less than 10, then the orange indicator does not blink.

Code Description
2 Room temperature sensor malfunction
3 Malfunction of the temperature sensor of the internal heat exchanger Tc
6 Malfunction of the reversing valve of the outdoor unit
8 Malfunction of the fan motor in the indoor unit
9 Power is not supplied to the indoor unit
11 Malfunction drainage pump or other drainage problems
12 Error in indoor unit software (wrong addressing)
13 Configuration error
14 Signal Loss central system management
15 Malfunction of the indoor heat exchanger temperature sensor Tcj
18 Malfunction of the outdoor unit control unit (G-Tr short circuit protection)
20 Error in block position recognition circuit
21 Malfunction of the current sensor in the outdoor unit
22 Malfunction of the outdoor heat exchanger temperature sensor
23 Discharge temperature sensor malfunction
24 Outdoor unit fan failure
26 Other outdoor unit malfunction
27 Outdoor unit compressor blocked
27 Invalid discharge temperature
29 Outdoor unit compressor failure
31 Increased pressure in the circuit of the outdoor unit

If the CARRIER air conditioner does not work, this is for us!

Error codes for Chigo air conditioners

If the CHIGO air conditioner does not work, this is for us!

Error codes for Daewoo air conditioners

Error code Cause of malfunction
F6 PG motor faults
F7 Indoor TEMP sensor faults
F8 Indoor coil pipe TEMP sensor faults
F9 Outdoor coil pipe TEMP sensor faults

If the Daewoo air conditioner does not work, this is for us!

Error codes for Fujitsu General air conditioners

Fujitsu General Ltd. introduced to the market New Product for diagnostics of split systems and multi-split systems GENERAL. The tool is a set of adapters connecting outdoor unit with a computer, and a PC program. With their help, a specialist conducting equipment diagnostics can see in real time the parameters of the compressor, fan motor, EEV, sensor readings, as well as an error log. In the process of testing, it is possible to record a work log with the issuance of a report.

The adapter is suitable for working with multi-split systems, as well as with most inverter split systems (wall, ceiling, channel, cassette).

Modern Fujitsu General air conditioners have a very advanced self-diagnosis system, according to the results of which the control system, when a particular malfunction is detected, blocks the operation of the entire device and at the same time reports the cause of the malfunction.

The Fujitsu General air conditioner control system reports any malfunctions by flashing an LED on the panel of the indoor (in some cases outdoor) unit. When a particular malfunction of the air conditioner is detected, the LEDs light up or flash in a certain sequence, which corresponds to the detected error. If the air conditioner control system has detected more than one error, then the malfunction with the highest priority is displayed first, and then all the others.

Error codes for Fujitsu General air conditioners are shown in the table.
Cause of malfunction Error display
OPERATION (red) TIMER (green) SWING (orange)
Indoor unit board failure ABOUT ABOUT -
Room temperature sensor wire open (indoor unit) 2 X ABOUT -
Short circuit in the room temperature sensor circuit (indoor unit) 2 X ABOUT ABOUT
Indoor unit piping sensor wire open 3 X ABOUT -
Short circuit in the indoor unit piping sensor circuit 3 X ABOUT ABOUT
Faulty indoor unit fan 6 X ABOUT -

For some models (see list *), depending on the error, the OPERATION, TIMER, SWING indicators work according to the following principle: ABOUT- fast blinking; X- slow blinking; - OFF

* Внутренний блок: ASG18FBAJ, ASG18FBBJ, ASG18UBAJ, ASG18UBBJ, ASG24FBBJ, ASG30FBBJ, ASG18FBBX, ASG18UBBN, ASG24FBBN, ASG24UBBN, AWG18FBAJ, AWG18FBBJ, AWG18UBAJ, AWG18UBBJ, AWG24FBBJ, AWG24UBBJ, AWG30FBBJ, AWG30UBBJ, AWG14UBBJ, ABG14FBBJ, ABG14FBBJ, ABG18FBBJ, ABG18FBBJ, ABG181BBJ, ABG181BBJ, ABG24FBBJ, ABG24FBBJ, ABG241BBJ, ABG241BBJ, AWG24FBAJ, AWG24UBAJ.
* Внешний блок: AOG18FNAK, AOG18FNBK, AOG18UNAKL, AOG18UNBKL, AOG24FNBK, AOG24UXBKL, AOG30UNBDL, AOG18FNBX, AOG18UXBXL, AOG24FXBX, AOG24UXBXL, AOG18FNAK, AOG18FXBK, AOG18UNAKL, AOG18UXBKL, AOG24FNBK, AOG24UXBKL, AOG30FNBDL, AOG30UNBDL, AOG14USBJ, AOG14FNBK, AOG14FXBX, AOG18FNBK, AOG18FXBX, AOG18UXBKL, AOG18UNBNL, AOG24FNBK, AOG24FXBX, AOG241XBKL, AOG24UXBXL, AOG24FXAD, AOG24UXADL

If the Fujitsu General air conditioner does not work, this is for us!

Error codes for Haier air conditioners

Repair of air conditioners HAIER (HAYER) is carried out on the basis of an analysis of the operating parameters of devices and fault codes.

If there are no errors or malfunctions, but the unit does not start, the start conditions may not be as required. In this case, the following standby codes will be displayed on the display of the head unit:

Error codes and malfunctions of indoor units of HAIER air conditioners

Remote display indication Number of flashes LED5 / Timer Description of the fault
01 1 Tai Ambient Temperature Sensor Malfunction
02 2 Malfunction of the temperature sensor of the heat exchanger TC1
03 3 Malfunction of the temperature sensor of the heat exchanger TC2
04 4 Dual Energy Source Temperature Sensor Malfunction
05 5 Indoor unit board EEPROM error
06 6 No communication between indoor and outdoor units
07 7 No communication between indoor unit and wired controller
08 8 Condensate drain error
09 9 Duplicate indoor unit address
0A 10 Duplicate indoor unit central address
Fault codes outdoor unit 20 Corresponding malfunction of the outdoor unit

Error codes and malfunctions of the inverter outdoor unit

Remote display indication Error code Description of the fault
20-0 Frost protection sensor t error TE1 AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in cooling mode, if the sensor is faulty, the unit does not use its readings, except for the defrost function or for 3 minutes. after its completion; no alarm
20-1 Frost protection t sensor error TE2
21 Outside air temperature sensor error Ta
22 Suction temperature sensor error Ts AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds. in defrost mode or for 3 min. after its completion; there is no alarm.
23 Discharge temperature sensor error Td After 5 minutes of compressor operation, the AD value is less than 11 (open circuit) or greater than 1012 (closed circuit) for more than 60 seconds. during start-up, in defrost mode or for 3 min. after its completion; no alarm
24 Toil oil temperature sensor error AD value is less than 11 (loop open) or greater than 1012 (loop closed) for more than 60 seconds, (loop closed) for 60 seconds; if within 5 minutes Ta 2 -10°C or ET< -10®С, сигнала тревоги нет.

The tables show only some of the HAIER air conditioner trouble codes. We remind you that HAIER air conditioners are technically sophisticated equipment. Error codes are provided for qualified and certified technicians. That is, for those who are professionally engaged in the repair of HAIER air conditioners, and not for ordinary users. Trust the repair of HAIER air conditioners to professionals.

If the Haier air conditioner does not work, this is for us!

Hisense Air Conditioner Error Codes

If a malfunction occurs, press the Sleep button on the remote control 4 times - the error code will light up on the 7-segment display (see table below). If there are several errors, then press the Sleep button 4 times again - the LED indicator will light up with the following error code.

Updated remote remote control, which has 4 modes of operation of the Sleep button, allows you to set 4 different combinations. When using it to check error codes, you must press the "Sleep" button 10 times. After that, error codes will start to be displayed.

Code Cause of malfunction
1 Outdoor heat exchanger temperature sensor error
2 Compressor discharge temperature sensor error
5 Integral Power Module (IPM) protection trip
6 Operation of the protection device against overvoltage or undervoltage in the network alternating current
7 Communication error between indoor and outdoor units
8 Overload protection device
10 Communication error between two microcircuits (control and drive) in a printed
11 Outdoor unit EEPROM memory error
12 Tripping of the protection device at low outside temperatures
13 Tripping of the safety device as a result of excessive temperature in
14 Outside air temperature sensor error
15 Compressor thermal protection trip due to overheating
16 Operation of the heat exchanger frost protection or overload protection device when the indoor unit is operating in heating mode
17 Compensation device reactive power(PFC)
18 DC compressor start error
19 Compressor drive error

Error codes for IGC air conditioners

IMS MINI (IMS-EM080NH, IMS-EM100NH, IMS-EM120NH, IMS-EM140NH, IMS-EM160NH)
Code Malfunction
CH Liquid pipe thermistor failure
CJ Temperature sensor malfunction
E6 Suction tube temperature protection frequency limits "TS"
E7 Protection Frequency Limits average temperature external capacitor
E8 Protective stop of external capacitor
E9 Compressor frequency limits over high temperature
F4 Low pressure sensor problems
F5 Low Pressure Transmitter Protection Limits for Ultra High or Ultra Low Frequency
F6 Low pressure safety shutdown for ultra-high or ultra-low frequency
H8 Constant frequency compressor overcurrent protection 1
H9 Constant frequency compressor overcurrent protection 2
ON Input voltage overvoltage and undervoltage protection
NS Incorrect phase sequence of fixed frequency compressor 1
HH Wrong phase sequence frequency converter compressor
HJ Wrong phase sequence of fixed frequency compressor 2
J4 Communication error with control panel and fan motor
J5 Error setting the address or load settings of the outdoor unit
38 Radiator temperature protection frequency limits
39 Radiator shutdown
3A DC fan protection
3C DC fan surge protection
3H Power on error or asynchronous fan operation
3J DC fan surge protection

Error codes for Kentatsu air conditioners

Error codes Kentatsu KSVP-HF

E2 - room temperature sensor malfunction
EЗ - malfunction of the evaporator temperature sensor
E4 - malfunction of the temperature sensor of the outdoor unit
E6 - outdoor unit malfunction
E7 - EEPROM error
E8 - excess water level

Error codes Kentatsu KSKT-HF channel type

E0 - Faulty room temperature sensor
E1 - Faulty evaporator temperature sensor
E2 - Faulty outdoor unit temperature sensor
E3 - outdoor unit defective
E4 - faulty drain pump temperature sensor
E5 - EEPROM error
E6 - rising water level

Error codes Kentatsu KSFU models: KSFU/KSRU76HFDN3, KSFU/KSRU140HFDN3

P4 - thermal protection of the evaporator of the indoor unit
P5 - thermal protection of the capacitor of the external unit
P9 - protection of the defrost function or creation of a comfortable air flow
E1 - open or short circuit in the temperature sensor circuit T1


E6 - outdoor unit protection

Error Codes Kentatsu KSGH/KSRH

Models: KSGH/KSRH21CFDN1 KSGH/KSRH26CFDN1, KSGH/KSRH35CFDN1 KSGH/KSRH53CFDN1, KSGH/KSRH21HFDN1 KSGH/KSRH26HFDN1, KSGH/KSRH35HFDN1
E1 - EEPROM error (non-volatile memory on the board)
E2 - zero crossing error
EЗ - abnormal fan speed
E4 - compressor current protection tripped 4 times
E5 - indoor air temperature sensor shorted / broken
E6 - evaporator temperature sensor shorted / broken

Kentatsu floor type error codes KSFU70XFAN1 / KSRU70HFAN1, KSFU120XFAN3 / KSRU120HFAN3

P4 - evaporator temperature protection
P5 - condenser temperature protection
P7 - Discharge temperature too high. Compressor protection enabled
P9 - too much low temperature outside air, when increased, the protection will turn off automatically
P10 - outlet pressure protection
P11 - suction pressure protection
P12 - overcurrent protection
E1 - indoor air temperature sensor T1 shorted / broken
E2 - evaporator temperature sensor T2 shorted / open
E3 - T3 condenser temperature sensor short/open
E4 - outdoor temperature sensor closed T4 shorted / broken
E5 - communication between the indoor and outdoor units is broken
E6 - outdoor unit protection
E10 - compressor suction pressure error
E13 - compressor phase error
E14 - incorrect compressor phasing
HS - start defrost

If the Kentatsu air conditioner does not work, this is for us!

Error codes for LG air conditioners

Code Cause of malfunction
F01 Open / short circuit room room (air) temperature sensor of the indoor unit
F02 Open/short circuit of the pipe temperature sensor of the indoor unit
F03 Lack of communication between the control panel and the main control board for more than 2 minutes
F04 Open / short pipe temperature sensor of the outdoor unit
F05 Open / short circuit room air temperature sensor of the outdoor unit
CH01 Malfunction of one of the thermistors of the board (break or short circuit) of the indoor, wall-mounted unit of the split system - control of the temperature of the incoming air and tube gas circuit air conditioner
CH02 Malfunction of one of the thermistors (break or short circuit) of the outdoor unit: inlet air temperature sensor or gas circuit pipe temperature sensor
CH03 The air conditioner works simultaneously for heating and cooling the air
CH04 Compressor overload protection system included
CH05 Communication error between the indoor and outdoor units of the split system
CH06 The current consumption of one or more actuators of the outdoor unit-relay was briefly above the norm
CH07 Current consumption of the entire outdoor unit long time was above normal
CH08 Fan motor failure
CH09 4-way valve malfunction
CH10 The thermistor for controlling the temperature of the compressor housing of the split system is faulty (open or short circuit)

LGMV is a mobile application developed by the manufacturer for remote monitoring operating parameters of LG air conditioning systems. The application helps engineers assess the current state of equipment. The analysis is based on a multi-year operation cycle. The program helps not only to quickly identify problems in the system, but also gives recommendations for resolving the issue.

The LGMV diagnostic system provides monitoring of system operating parameters, prevention and prevention of system malfunctions. All this certainly simplifies diagnostics and commissioning. LGMV consists of a wireless communication module and a free smartphone app. To use the LGMV mobile application, an exclusive Bluetooth module is required, the corresponding connector of which must be connected to the CN-LGMV port on the main board of the outdoor unit.

LGMV main features:

Visual display of key information about the operation of the air conditioner.
Graphic indication of pressure and other parameters.
Controls the operation mode of the indoor units when the unit is connected to the outdoor unit.
Saving data on the operation of the air conditioner as a file.
Operation report — the result of the testing operation is generated into an HTML document.
Error number indication and support for error search in the list from PDF document.

Mobile LGMV can be downloaded, for example, from Google Play as a product of LG Electronics, Inc. as a tool for Maintenance, troubleshooting for LG air conditioning systems. Mobile app LGMV uses a limited resource on a smartphone and processes data in real time. Data monitoring may be difficult or data may not be fully saved if the performance of the smartphone is poor.

It is recommended to use a high performance smartphone. If system resources are insufficient due to other Internet applications that are enabled, data monitoring may fail in addition to monitoring. The monitoring function and saving function may not work fully. And also Bluetooth communication connection can be disabled. In addition, the application may be disabled due to a lack of resources or an unexpected error.

The communication level may increase depending on the number of outdoor and indoor units. Bluetooth transmission distance may be shortened to the point of turning off data transmission depending on the weather or conditions. environment(electromagnetic waves or obstacle), etc. It is recommended to use the Bluetooth module for a short distance.

If the LG air conditioner does not work, this is for us!

Error codes for MDV air conditioners

Error indication on MDV indoor unit

If you need diagnostics of the MDV air conditioner - this is for us!

Error indication on external MDV unit
E0 eeprom error
E1 Error on the temperature sensors of the indoor unit 1
E2 Error on the temperature sensors of the indoor unit 2
E3 Error on the temperature sensors of the indoor unit 3
E4 Outdoor unit temperature sensor error
E5 High or low voltage protection
E6 Error on the temperature sensors of the indoor unit 4
E7 No communication between control and inverter boards
P0 Compressor overheating protection
P1 Protection by high pressure- only for M4OCi
P2 Protection by low pressure- only for M4OCi
P3 Compressor overcurrent protection
R4 Inverter module protection tripped
R5 Low outdoor temperature protection -7°C
P6 High condensing temperature protection

If the MDV air conditioner does not work, this is for us!

Mitsubishi Electric Air Conditioner Error Codes

If the Mitsubishi Electric air conditioner does not work, this is for us!

Mitsubishi Heavy Air Conditioner Error Codes

If the Mitsubishi Heavy air conditioner does not work, this is for us!

Error codes for Wisnow air conditioners

If the Wisnow air conditioner does not work, this is for us!

Error codes for Polaris air conditioners

If the Polaris air conditioner does not work, this is for us!

Sanyo Air Conditioner Error Codes

Description of the malfunctions that are indicated on the board of the SANYO W-ECO MULTI SYSTEM outdoor unit. Valid for SPW-CR1503GDYH8, SPW-CR1903GDYH8, SPW-CR703GDCH8, SPW-CR903GDCH8, SPW-C1503GDYH8, SPW-C1903GDYH8, SPW-C703GDCH8, SPW-C903GDCH8.

If the Sanyo air conditioner does not work, this is for us!

Sharp Air Conditioner Error Codes

For example, fault indication in SHARP air conditioners models AY-A184E / AE-A184E, AY-A244E / AE-A244E.

If the Sharp air conditioner does not work, this is for us!

Error codes for Toshiba air conditioners

Code Malfunction
00-0s indoor air temperature sensor error or indoor unit board error
00-0d error of the temperature sensor of the radiator or control board
00-11 defective board or fan motor
00-12 need to replace control board
01-04 fuses on the board burned out, incorrect interconnection, board burned out
01-05 inverter board error
02-14 inverter overcurrent
02-16 short circuit between compressor windings
02-17 current sensor error
02-18 error of temperature sensors, PC board
02-19 TD temperature sensor error, PC board
02-1a outdoor unit fan error - overcurrent, blocked, burnt motor or board
02-1b condenser temperature sensor defective or board
02-1c compressor did not start within 20 seconds
03-07 lack of refrigerant, inverter board error
03-1d defective compressor
03-1e suction tube sensor error TD, not enough refrigerant
03-1f compressor does not work due to supply voltage, overload of the refrigeration circuit
03-08 four-way valve malfunction

If the Toshiba air conditioner does not work, this is for us!

The work performed during the diagnostics corresponds to the work performed during. The only difference is that during the diagnostics, all the main parameters of the equipment operation are checked and recorded, and during the service, the identified deviations from the norm are eliminated.

The list of works in the diagnosis of air conditioning

During the diagnosis of the air conditioner, firstly, an external examination is carried out for the absence mechanical damage. Not only hull, but also hydraulic and electrical parts of the equipment are inspected. In addition, the reliability of the fasteners of the external and internal units is checked. As well as the quality of the clamps of all contact connections of electrical equipment. Before turning on the equipment, it is necessary to check the condition of the air filters. They must be not only clean, but also without damage. After inspection, as a rule, switching to the "cooling" mode is performed. Use the remote control to test the system.

During the functional test, the indication of the air conditioner modes is evaluated, as well as the operation of the mechanically driven exit blinds. One of the indirect indicators of the efficiency of the system is the control of the temperature of dry air at the inlet and outlet of the evaporator. With the help of pressure gauges, the average suction / discharge pressure is measured (with free access to the outdoor unit). Of course, it is mandatory to check the tightness of the connection between the indoor and outdoor units. In addition, you need to make sure that there are no leaks in drainage system conditioner.

If something went wrong

The specialist can also judge the nature of the malfunction by the “behavior” of the air conditioner. For example, if the air conditioner turns on and immediately turns off, after which an error message is displayed - most likely, the matter is in the sensors (malfunction of the air temperature sensors or the evaporator).

If the air conditioner turns on, runs for 15-20 seconds, and then turns off, the indoor unit fan motor is most likely defective (rotation speed is lower than the set rpm).

If the air conditioner does not turn on at all and at the same time all the LEDs flash (or do not light up), most likely, a failure has occurred printed circuit board management.

Simultaneous flashing of all indicator lamps of the air conditioner, as a rule, means only a failure of the program settings of the control board. Most likely, this is due to the non-compliance with the GOSTs of the network parameters, for example, due to a power surge in the network. It is not difficult to eliminate this malfunction - it is enough just to reprogram the main control board. Since information about codes is provided only to authorized service centers, in this case it is necessary to contact our specialists.

Before…

If your air conditioner does not work, first of all make sure that the air conditioner is securely connected to the outlet. Check the circuit breaker or fuse on the supply line, if necessary restart the circuit breaker or replace the fuse. Read the user manual again and make sure all modes are set correctly.

Doing it yourself will save you money. Because in many cases the engineer you called, after doing what you can easily do yourself, will charge you for the false call.

If these steps do not help, then contact the sales organization that sold you the air conditioner. Or contact an authorized service center of the air conditioner manufacturer. Undoubtedly, this is the best, fastest and reliable way restore the performance of your air conditioner. The sales organization that sold the air conditioner should give you information on how to contact them. This information is available not only in the warranty card, but also on the manufacturer's website in the appropriate regional section.

Air conditioner test mode

To facilitate diagnostics, modern air conditioners have a so-called test mode. Compared to the operating mode, the air conditioner turns on in cooling mode and does not respond to sensor readings and air temperature. That is, in the test mode, the air conditioner will function as long as it is necessary for the service engineer to study the operation of the system units. After turning off the test mode, the air conditioner will return to normal operation.

IN samsung air conditioners a test mode is also provided. To enter the test mode, press the on / off button on the indoor unit and hold it for five seconds. At the same time, the temperature indicator displays the installed software settings option at a second interval, for example, 0b0000-1730F8: 0b00001730F80b (only for models with a temperature indicator).

When testing the operation of the air conditioner, the cooling mode is switched on with the following restrictions:
- The compressor is forced to run in cooling mode without turning on/off according to the set internal temperature, without defrosting mode;
- Vane, guide air flow up/down - turn up/down mode;
- The indoor fan rotates at high speed.

Error codes for Baloo air conditioners are required in order to timely identify the malfunction and contact the master to fix it. It should be noted that in some cases the slightest delay becomes critical, so it is better to monitor the appearance of information on the scoreboard.

True, the errors of Baloo air conditioners directly depend on the series. Because the hardware is different. software, which means that it informs a person about malfunctions in different ways. So, you should consider all possible codes depending on the series.

Mistakes on the example of Ballu MFS2

Errors of air conditioners Baloo series MFS2:

  • E1, E2, E3, E4 - Ballu air conditioner error, indicating that the temperature sensor was broken or shorted;
  • E6 shows the emergency activation of the protection of the outdoor unit;
  • E8 - Ballu air conditioner error, requiring cleaning of the electrostatic filter;
  • P4 - the compressor automatically turned off, as an error appeared on the evaporator sensor, which occurs when the temperature threshold is overcome;
  • P5 - this error code air conditioner Ballu shows when an error occurs on the condenser sensor;
  • P6 will prompt that the defrosting process has started automatically.

The number of codes shows how much information a person receives about the operation of his own equipment.

Accordingly, he can turn to specialists at the right time.

Below is the maximum full list codes of errors and malfunctions encountered in this technique in general.

Errors air conditioner Balu series BSC, BR, BV

  • E1, this air conditioner error code is displayed when the indoor air temperature sensor does not work properly;
  • E2 - evaporator temperature sensor error;
  • E5 indicates that an error has occurred in the outdoor unit, resulting in automatic start protection mode;
  • E6 are Baloo air conditioner errors showing a malfunction of the fan motor in the indoor unit.

It is immediately clear that the last three series have a much smaller number of codes. On the one hand, this shows how stable models are considered. On the other hand, the user receives less information, which often leads to difficult situations and additional diagnostics of cassette air conditioner models.

Air conditioner error codes - helpful information that appears on the equipment screen. If you correctly recognize them, you will be able to find out exactly which malfunction should be fixed. Because of this, maintenance takes a minimum of time, which means that the owner does not have to suffer from a lack of equipment.

With Gree air conditioners and split systems, repairs are easier than with hi-fay series models.

Self-diagnosis of Gree air conditioners

What explains this, the layman asks?

The explanation is simple Gree: codes. On Gree air conditioners and split systems, there are not many protection system sensors. Those. everything is simplified.

  • Internal self-diagnosis of Gree air conditioners unified and almost identical in error positions to inexpensive air conditioners, such as Pioneer, General Climate, Lessar and others.

You will laugh, but for example, the catalog of Supra air conditioners has not even changed the name of the outdoor unit, perhaps there are not enough skills in Photoshop, perhaps they did not consider it necessary.

In a word, how were Supra air conditioners certified in Russia? It's a mystery to me. Supra Catalog!! In faith. Heh...

Self-diagnosis of Gree air conditioners is, -

  • high pressure protection
  • protected from freezing of the evaporator,
  • Compressor overload protection,
  • Errors in switching the air conditioner during installation, confusing wires,
  • And errors of temperature sensors of the evaporator and condenser.

Everything, agree not much. Gree, like an air conditioner, is functionally simple, so there are not many error codes.
There are drawbacks to this simplification - these are weak control board varistors, insufficient smoothing

Error codes table, continued.

currents during voltage surges. A trifle, but it must be borne in mind when repairing air conditioners Gree and their analogues.

Example: country house. The owners, leaving the dacha, usually de-energize the building with a common switch.
Those. extinguished and everything, calmed down. We arrived ... They turned on the light with the same switch, but the air conditioner, refrigerator, or other household appliances did not work. Why? The answer is simple.

When the power is turned on with a load, current and voltage surges occur.

Varistors that smooth out voltage surges cannot cope with the current load and burn out, burn well with smoke and soot, in the absence of a protective sheath, as a rule, together with the fuse of the control board of the indoor unit of the split system.

There are "specialists" who use wire when burning a fuse. Can you do that? It is possible, but then, in addition to the varistors, the control board, the fan motor of the indoor unit will also burn out, and ... it rushed up to the compressor windings of the outdoor unit of the air conditioner.

Fireworks at the cottage. - Expensive repairs.

Troubleshooting and breakdowns of the air conditioner, Gree: codes, as usual, we start with ...

- refrigeration circuit malfunctions,

- malfunctions of the electrical part, system e-mail. power supply and air conditioning control.
Source:

Error map, mapping. Primary diagnostics of the system.

GREE Semi-industrial, industrial air conditioners, - error codes.

Error Code = E1
Compressor, pressure surges (beep).

Error Code = E2
Faulty coil

Error code = E3
Low pressure air conditioning compressor activated (beep)

Error code = F0
Faulty room temperature sensor.

Error code = F1
Incorrect sensor resistance.

Error code = F2

  • The temperature sensor of the outdoor unit of the air conditioner has tripped.

Error code = F3
Temperature sensor circuit open.

GREE Split air conditioners Error code...

The cause of the malfunction, - the refrigerant system is highly protected, - pressure.
code = E1

Gree LED blinks 1 time.
Indicator, - cooling =
Heating indicator =

The cause of the Gree malfunction is frost protection.
code = E2

Air conditioner start LED = LED blinks 2 times.
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Compressor exhaust high temperature protection.
code = E4

Air conditioner start LED = flashes 4 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - AC overcurrent protection
code = E5

Air conditioner start LED = LED blinks 5 times
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is a communication failure between the indoor unit of the air conditioner and the outdoor unit of the split system.
code = E6

Gree air conditioner start LED = blinks 6 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Anti-high temperature protection
code = E8

Air conditioner start LED = flashes 8 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - No feedback internal engine fan
code = H6

Air conditioner start LED = flashes 11 times
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Jumper cap faulty protection
code = C5

Air conditioner start LED = flashes 15 times
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Closed ambient sensor open, no contact or short circuit
code = F1

Indicator, - cooling = LED flashes 1 time
Heating indicator =

Name of sensor malfunction or failure = Indoor tube open, no contact or short circuit
code = F2

Air conditioning start LED =
Indicator, - cooling = LED flashes 2 times
Heating indicator =

The cause of the malfunction, - the external ambient sensor is open, there is no contact or a short circuit
code = F3

Air conditioning start LED =
Indicator, - cooling = LED flashes 3 times
Heating indicator =

Cause of malfunction, - Outer tube sensor open, no contact or short circuit
code = F4

Air conditioning start LED =
Indicator, - cooling = flashes 4 times
Heating indicator =

Name = malfunction or failure of the exhaust sensor open, no contact or short circuit
code = F5

Air conditioning start LED =
Indicator, - cooling = LED flashes 5 times
Heating indicator =

Cause of malfunction, - Over load limit / frequency reduction
code = F6

Air conditioning start LED =
Indicator, - cooling = Blink 6 times
Heating indicator =

Cause of malfunction, - Over current limit / frequency output
code = F8

Air conditioning start LED =
Indicator, - cooling = flashes 8 times
Heating indicator =

The cause of the malfunction, - High exhaust gas temperature limit / frequency reduction
code = F9

Air conditioning start LED =
Indicator, - cooling flash = 9 times
Heating indicator =

The cause of the malfunction, - Overvoltage protection for Ru
code=PH

Air conditioning start LED =
Indicator, - cooling = flashes 11 times
Heating indicator =

Cause of the malfunction, - alternating current detection of faulty circuits
code = U5

Air conditioning start LED =
Indicator, - cooling = flashes 13 times
Heating indicator =

The cause of the malfunction, - Compressor reverse protection
code = U4

Air conditioning start LED =
Indicator, - cooling = flashes 14 times
Heating indicator =

The cause of the malfunction, - Over the compressor phase current protection
code = P5

Air conditioning start LED =
Indicator, - cooling = flashes 15 times
Heating indicator =

The cause of the malfunction is the inlet of the malfucntion by the sensor tube
code = b5

Air conditioning start LED =
Indicator, - cooling = flashes 19 times
Heating indicator =

The cause of the malfunction, - The open DC fan motor is defective.
code = L3

Air conditioning start LED =
Indicator, - cooling = flashes 21 times
Heating indicator =

Cause of the malfunction, - Output malfunction or breakage of the tube sensor
code = b7

Air conditioning start LED =
Indicator, - cooling = flash 22 times
Heating indicator =

The cause of the malfunction, - The compressor overload sensor is defective.
code=FE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - Defrosting
code=h3

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED blinks 1 time

The cause of the malfunction is static dust protection cleaning
code = H2

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED blinks 2 times

Cause of malfunction, - Compressor overload protection
code = H3

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED flashes 3 times

Cause of malfunction, - System abnormal protection
code = H4

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 4 times

The cause of the malfunction, - IPM protection
code = H5

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = LED flashes 5 times

Cause of malfunction - PFC protection
code=HC

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 6 times

Cause of malfunction, - Compressor step loss protection
code = H7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator flash = 7 times

Cause of the malfunction, - Heating against high frequency temperature drop
code=HO

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 10 times

Cause of malfunction - Startup failure
code = Lc

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 11 times

Cause of malfunction, - Phase failure protection compressor
code = U2

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 12 times

Cause of the malfunction, - Phase current compressor faulty detection circuits
code = U1

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 13 times

Cause of malfunction, - Compressor degaussing protection
code=HE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 14 times

The cause of the malfunction, - EEPROM loading is defective.
code=EE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 15 times

The cause of the malfunction is a communication failure between motherboard and board drivers
code = P6

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 16 times

The cause of the malfunction is a malfunction of the charge capacitor
code=PU

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 17 times

The cause of the malfunction is the IPM of the sensor circuit is faulty.
code = P7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 18 times

The cause of the malfunction, - IPM high-temperature protection
code = P8

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 19 times

Cause of the malfunction, - PN protection voltage drop
code = U3

Air conditioning start LED =
Indicator, - cooling = flashes 20 times
Heating indicator =

The cause of the malfunction is low voltage protection PN
code=PL

Air conditioning start LED =
Indicator, - cooling =
Heating indicator = flashes 21 times

Cause of the malfunction, - The current detection circuit is faulty or the current sensor is faulty or broken
code = Rs

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - Compressor phase failure protection
code = Ld

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - Compressor or rotary protection blocked
code=LE

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - IPM is more than the temperature limit / frequency reduction
code=EU

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction - 4-way reversal valve abnormal
code = U7

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction is the shutdown of the exhaust gas temperature sensor
code = U8

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of malfunction, - AC zero voltage error detection
code = U9

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

The cause of the malfunction, - Over the tube frequency temperature difference
code=FA

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Cause of the malfunction, - Anti-freeze limit / frequency reduction
code=FH

Air conditioning start LED =
Indicator, - cooling =
Heating indicator =

Models: brand air conditioner repair KFR-32GW/BP, KFR-45LW/D, KFR-3502GW/BP, KFR-2501GW, KFR-45LW, KFR-3301GW, KFR-3201GWCPU, KFR-2608GW/BP and other KFR series, PDF fail.